LX-WTP-042Acid Corrosion Inhibitor — for HCl
Protecting steel during hydrochloric acid descaling, pickling and cleaning
Share your quantity, grade and delivery location. Our desk confirms make, specification, packaging and lead time in writing, typically within one business day.
Acid corrosion inhibitor for sulphamic acid is an additive blended into sulphamic acid descaling solutions. Sulphamic acid is milder and safer to handle than hydrochloric acid, but still attacks steel, copper and brass at cleaning temperatures. The inhibitor adsorbs on metal surfaces to limit this attack while scale dissolves, and is often supplied with a wetting agent.
It is used when descaling boilers, condensers, chillers, heat exchangers and cooling jackets with sulphamic acid. Keep the solution below the temperature recommended for the inhibitor, since sulphamic acid hydrolyses when hot. Dose is a small percentage of the acid charge, adjusted for metallurgy and scale load.