Water Treatment Programme Chemicals

RO Biocide

RO Biocide — RO Plant Chemicals
RO Plant ChemicalsLX-WTP-025

At a glance

Typical use
Controlling biofouling in RO membranes and pretreatment without chlorine damage
Product code
LX-WTP-025
Availability
Available on Request
Request a quote

Share your quantity, grade and delivery location. Our desk confirms make, specification, packaging and lead time in writing, typically within one business day.

Talk to Sales

Product Overview

RO Biocide is a non-oxidising biocide for reverse osmosis systems, usually based on DBNPA (dibromonitrilopropionamide). Polyamide thin-film membranes are damaged by free chlorine, so a non-oxidising product is used to control bacteria and the biofilm that raises differential pressure and lowers flux. DBNPA acts fast and breaks down in water into less harmful products.

It is slug-dosed into the RO feed, intermittently or during cleaning and lay-up. The permeate from dosing periods is usually sent to drain in potable or food plants. Check membrane-maker compatibility, and handle the concentrate with gloves and eye protection.

Applications

RO membranes — biofouling control during operation
Membrane cleaning — sanitising after chemical cleans
RO lay-up — preserving idle membranes
Pretreatment lines — bacterial control in feed pipework